콘텐츠로 건너뛰기
Merck

57265

Visiprep SPE Vacuum Manifold

DL (Disposable Liner), 24-port model

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

UNSPSC Code:
12352200
NACRES:
NB.21
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


Quality Level

material

PTFE frit, polypropylene tube

product line

Visiprep

technique(s)

solid phase extraction (SPE): suitable

application(s)

food and beverages

General description

SPE is a form of chromatography, and, as with other chromatographic techniques, control of flow rate is critical for maintaining reproducible extractions. Unlike other vacuum manifolds, the Visiprep system contains a patented valve system that allows for precise flow control through each SPE tube via rotating, independent, screw-type valves situated in each port within the manifold cover. Visiprep vacuum manifolds allow you to process up to 12 (12-port version) or 24 (24-port version) SPE samples simultaneously. Spacing between ports are slightly smaller on the 24-port versions than the 12-port versions so consideration of tube sizes is recommended.
The Visiprep DL (Disposable Liner) Vacuum Manifold eliminates the possibility of cross-contamination when processing a new sample on the same port. The liner consists of a PP female luer hub that attaches to the SPE, and thin-walled PTFE tubing that is threaded through the SPE port. This ensures that all SPE port and valve surfaces coming in contact with the sample can be replaced following each extraction.

Application

Visiprep SPE Vacuum Manifold was used to perform solid phase extraction to separate polyphenols from grapes, in order to determine the polyphenol content using LC-MS analysis. It was also used for concentration and purification of solvent extracts from surface water and sewage water sediments. Furthermore it was also used to extract and determine estrone in water using solid-phase extraction-enzyme-linked immunosorbent assay (SPE-ELISA).

Features and Benefits

  • Patented screw-type valves within each SPE port for precise flow control
  • Glass basin will not dissolve, fog, or discolor when exposed to solvents
  • Legs on cover allow user to easily rest cover on work surface when removed from the manifold
  • Screw-type solvent-resistant vacuum bleed gauge and valve offer better sealing and vacuum control. Valve takes 1/4″ vacuum tubing.
  • PP collection vessel rack accommodates autosampler vials; small scintillation vials (22.75 mm O.D. recommended); 10 and 16 mm test tubes; and 1, 2, 5, and 10 mL volumetric flasks. An optional plate for 20 mL scintillation vials is available for 12-port models.
Supplied with 100 disposable liners (Part No. 57059).

Legal Information

Visiprep is a trademark of Sigma-Aldrich Co. LLC


Still not finding the right product?

Explore all of our products under




가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문


프로토콜

Optimize β-glucuronidase hydrolysis for glucuronide metabolite analysis considering factors like time, temperature, pH, and enzyme concentration.

Paprika spice's PAH contamination risk due to environmental exposure highlights food safety concerns.

문서

Use QuEChERS methods to analyze samples of milk for veterinary drugs.

관련 콘텐츠

고상 추출은 크로마토그래피 분석을 위해 시료를 정제하여 데이터 품질을 개선하고 분석 컬럼을 보호합니다.

Bath Salts in Urine - Supel-Select SCX SPE and Ascentis Express HILIC Application Note

관련 콘텐츠 모두 보기

Guangdi Wang et al.
Journal of environmental monitoring : JEM, 14(5), 1353-1364 (2012-03-23)
Endocrine disrupting compounds (EDCs), represented by steroid hormones, organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), and bisphenol A have been determined in four sediment cores from the Gulf of Mexico, from New Orleans surface water (Lake Pontchartrain and Mississippi River), and
Angeles M Alonso Borbalán et al.
Journal of chromatography. A, 1012(1), 31-38 (2003-09-26)
There is considerable interest in the analysis of phenolic compounds due to their involvement in the organoleptic characteristics of foods and drinks, and their contribution to protection against cardiovascular diseases and cancers through their antioxidant activity. This article describes studies
Development of a solid-phase extraction-enzyme-linked immunosorbent assay method for the determination of estrone in water.
Li, Zhilan, et al.
Analytica Chimica Acta, 503, 171-177 (2004)



국제 무역 품목 번호

SKUGTIN
5705904061835552641
5702704061833667859
5726504061835552764