vapor density
1.6 (vs air)
vapor pressure
44.8 mmHg ( 20 °C)
assay
97.5-98.5% (T)
form
liquid
autoignition temp.
1004 °F
expl. lim.
57 %
technique(s)
LC/MS: suitable
impurities
1.5-2.5% water
evapn. residue
≤0.002%
bp
100-101 °C (lit.)
mp
8.2-8.4 °C (lit.)
density
1.22 g/mL at 25 °C (lit.)
anion traces
chloride (Cl-): ≤5 mg/kg, sulfate (SO42-): ≤5 mg/kg, sulfite (SO32-): ≤10 mg/kg
cation traces
Ca: ≤1.0 mg/kg, Co: ≤0.1 mg/kg, Cr: ≤0.1 mg/kg, Cu: ≤5.0 mg/kg, Fe: ≤0.5 mg/kg, Mn: ≤0.1 mg/kg, NH4+: ≤10 mg/kg, Ni: ≤0.1 mg/kg, Pb: ≤0.1 mg/kg, Zn: ≤0.5 mg/kg
SMILES string
OC=O
InChI
1S/CH2O2/c2-1-3/h1H,(H,2,3)
InChI key
BDAGIHXWWSANSR-UHFFFAOYSA-N
Legal Information
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 3 - Skin Corr. 1A
supp_hazards
저장 등급
3 - Flammable liquids
wgk
WGK 1
flash_point_f
121.1 °F - closed cup
flash_point_c
49.5 °C - closed cup
문서
Validate urine sample cleanup with HLB SPE for opioid analysis via LC-MS/MS using the Supel™ Swift HLB 96-well plate.
This application note describes the LC-MS-based quantitative analysis of known nitrosamine impurities following procedures 1 and 3 as given in USP general chapter <1469>.
LC-MS procedure, including sample extraction, for the determination of tryptamine hallucinogens, psilocin, and psilocybin in psilocybin mushrooms.
관련 콘텐츠
전체 솔루션을 알아보세요. 신뢰할 수 있는 제품과 정밀한 툴로 물, 폐수, 흙, 식품, 혈액 등이 포함된 다양한 샘플에서 PFAS 화합물의 양을 더욱 정확하게 측정할 수 있습니다.
Discover our complete solutions: Reliable products and precision tools to more accurately quantify PFAS compounds in diverse samples including water, wastewater, soil, food, blood, etc.
국제 무역 품목 번호
| SKU | GTIN |
|---|---|
| 246506-250G | 04061825866239 |
| 00940-50ML | 04065265030397 |
| 00940-10ML | 04065265030373 |
| 00940-250ML | 04065265030380 |