콘텐츠로 건너뛰기
Merck

88413

1-(2-Thiazolylazo)-2-naphthol

for spectrophotometric det. of Cd, Co, Cu, Mn, Ni, Tl, ≥99.0%

동의어(들):

2-(2-Hydroxy-1-naphthylazo)thiazole, TAN

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
C13H9N3OS
CAS 번호:
Molecular Weight:
255.30
UNSPSC Code:
23151817
NACRES:
NA.21
PubChem Substance ID:
EC Number:
214-555-3
Beilstein/REAXYS Number:
21172
MDL number:
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


Quality Level

assay

≥99.0% (CHN), ≥99.0%

form

powder

quality

for spectrophotometric det. of Cd, Co, Cu, Mn, Ni, Tl

technique(s)

UV/Vis spectroscopy: suitable

mp

138-139 °C

solubility

methanol: 10 mg/mL, clear

SMILES string

Oc1ccc2ccccc2c1\N=N\c3nccs3

InChI

1S/C13H9N3OS/c17-11-6-5-9-3-1-2-4-10(9)12(11)15-16-13-14-7-8-18-13/h1-8,17H/b16-15+

InChI key

IOMXCGDXEUDZAK-FOCLMDBBSA-N

Other Notes

Reagent for the extraction and spectrophotometric determination of metals, metallochromic indicator


저장 등급

13 - Non Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)



가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문



Serife Tokalioğlu et al.
Environmental monitoring and assessment, 152(1-4), 369-377 (2008-05-20)
A new method for separation and preconcentration of trace amounts of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) ions in various matrices was proposed. The method is based on the adsorption and chelation of the metal ions on a column containing
Y Sumi et al.
Histochemistry, 87(4), 327-329 (1987-01-01)
We describe a new autoradiographic technique for differentially demonstrating the presence of trace amounts of cadmium that remains unbound to metallothionein in tissue sections. This procedure involves [14C-1,4,5,8-naphthol]-1-(2-thiazolylazo)-2-naphthol (TAN) instead of a metal radioisotope. Tissue sections were stained using labeled
K C Teo et al.
The Analyst, 126(4), 534-537 (2001-05-09)
Cloud point extraction has been used for the preconcentration of manganese, after the formation of a complex with 1-(2-thiazolylazo)-2-naphthol (TAN), and later analysis by flame atomic absorption spectrometry using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The chemical variables affecting the separation