콘텐츠로 건너뛰기
Merck

72090

Neocuproine hydrochloride monohydrate

for spectrophotometric det. of Cu, ≥99.0%

동의어(들):

2,9-Dimethyl-1,10-phenanthroline hydrochloride

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
C14H12N2 · HCl · H2O
CAS 번호:
Molecular Weight:
262.73
UNSPSC Code:
23151816
NACRES:
NA.21
PubChem Substance ID:
MDL number:
Beilstein/REAXYS Number:
4584190
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


Quality Level

assay

≥99.0% (AT), ≥99.0%

form

powder

quality

for spectrophotometric det. of Cu

technique(s)

UV/Vis spectroscopy: suitable

SMILES string

Cl[H].[H]O[H].Cc1ccc2ccc3ccc(C)nc3c2n1

InChI

1S/C14H12N2.ClH.H2O/c1-9-3-5-11-7-8-12-6-4-10(2)16-14(12)13(11)15-9;;/h3-8H,1-2H3;1H;1H2

InChI key

APDYLFLZNGECIM-UHFFFAOYSA-N

Application

Neocuproine hydrochloride monohydrate has been used in measuring copper dissolution in Cu–Ni alloys using colorimetric method. It has also been used in preparing complexing agent solution in studying the antioxidant capacity assays in biological samples based on Cu reducing complexes. It may be used as a precursor for the preparation of neocuproine, used as an analytical reagent for the determination of copper in environmental samples using spectrophotometric technique.
Neocuproine hydrochloride monohydrate has been used in measuring copper dissolution in Cu–Ni alloys using colorimetric method. It has also been used in preparing complexing agent solution in studying the antioxidant capacity assays in biological samples based on Cu reducing complexes.


저장 등급

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves



가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문



Rapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection
Huang Y, et al.
Microchimica Acta, 166(3-4), 221-228 (2008)
Corrosion inhibitive action of cysteine on Cu?30Ni alloy in aerated 0.5 MH 2 SO 4.
Saifi, H., et al.
Materials Chemistry and Physics, 120.2, 661-669 (2010)
Insights on antioxidant assays for biological samples based on the reduction of copper complexes?the importance of analytical conditions.
Marques, Sara S., et al.
International Journal of Molecular Sciences, 15.7, 11387-11402 (2014)



국제 무역 품목 번호

SKUGTIN
72090-1G04061826148631
72090-5G04061832920962