콘텐츠로 건너뛰기
Merck

1.09060

Hydrochloric acid solution

c(HCl) = 0.1 mol/l (0.1 N), reag. Ph. Eur., reag. USP, volumetric solution for titration, Titripur®

동의어(들):

Hydrochloric acid solution, Hydrogen chloride solution

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
HCl
CAS 번호:
Molecular Weight:
36.46
NACRES:
NA.21
UNSPSC Code:
12352301
MDL number:
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


제품 이름

Hydrochloric acid solution, c(HCl) = 0.1 mol/l (0.1 N), Titripur®, reag. Ph. Eur., reag. USP

Quality Level

agency

reag. Ph. Eur., reag. USP, suitable for SM 2310, suitable for SM 2320

product line

Titripur®

form

liquid

quality

Analyzed in our ISO 17025 accredited QC lab

reaction suitability

reaction type: Acid-base reactions

packaging

Titripac® of

concentration

0.1 M

technique(s)

titration: suitable

pH

1.2 (20 °C in H2O)

density

1.00 g/cm3 at 20 °C

storage temp.

15-25°C

SMILES string

Cl

InChI

1S/ClH/h1H

InChI key

VEXZGXHMUGYJMC-UHFFFAOYSA-N

Application

Hydrochloric acid solution can be used as a titrant to determine:
  • Sodium bicarbonate content in fireworks compositions through potentiometric titration.
  • Total volatile basic nitrogen in fish samples.

Features and Benefits

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Packaging

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Titripac® packaging - all SKU-pack size numbers ending "4000, 4003, 9010, 9013" - more information on www.sigmaaldrich.com/Titripac

Analysis Note

Form liquid
Amount-of-substance concentration 0.0995 - 0.1005 mol/L
Measurement uncertainty ± 0.0003 mol/L
Traceability NIST SRM

TThe concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Other Notes

Replaces: HX0603A; HX0603A-8; HX0603A-6; HX0603A-3;

Legal Information

Titripac is a registered trademark of Merck KGaA, Darmstadt, Germany
Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under


pictograms

Corrosion

signalword

Warning

hcodes

Hazard Classifications

Met. Corr. 1

저장 등급

12 - Non Combustible Liquids



시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문


프로토콜

Method: Spectrophotometric Color Determination at 420 nm Zero adjustment For each measurement series, a zero adjustment is required. It is recommended to use the same cell for zero adjustment and for sample measurement. The zeroing procedure for the measurement series is automatically prompted by the instrument after entering the %RDS value.

APHA 10200-H는 추출용액의 측정에 대해 기술합니다. 위에서 명시한 시약을 이용하여 분석 방법을 영점 조정하면 분석용 정제수를 이용하여 분석 방법을 영점 조정했을 때와 비교 시 흡광도에 차이가 없었습니다. 그러므로 분석 방법을 영점 조정할 때 분석용 정제수 사용이 가능합니다.

문서

SmartChemicals enable wireless CoA data transfer, reducing human error in titration experiments.

관련 콘텐츠

칼 피셔 적정은 원료와 제품의 수분 함량을 측정하는 것으로, 널리 사용되는 분석 방법입니다.

Karl Fischer titration determines water content in raw materials and products, a widely used analytical method.

관련 콘텐츠 모두 보기