제품 이름
Hydrochloric acid solution, c(HCl) = 0.1 mol/l (0.1 N), Titripur®, reag. Ph. Eur., reag. USP
Quality Level
agency
reag. Ph. Eur., reag. USP, suitable for SM 2310, suitable for SM 2320
product line
Titripur®
form
liquid
quality
Analyzed in our ISO 17025 accredited QC lab
reaction suitability
reaction type: Acid-base reactions
packaging
Titripac® of
concentration
0.1 M
technique(s)
titration: suitable
pH
1.2 (20 °C in H2O)
density
1.00 g/cm3 at 20 °C
storage temp.
15-25°C
SMILES string
Cl
InChI
1S/ClH/h1H
InChI key
VEXZGXHMUGYJMC-UHFFFAOYSA-N
Application
- Sodium bicarbonate content in fireworks compositions through potentiometric titration.
- Total volatile basic nitrogen in fish samples.
Features and Benefits
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
Packaging
Titripac® packaging - all SKU-pack size numbers ending "4000, 4003, 9010, 9013" - more information on www.sigmaaldrich.com/Titripac
Analysis Note
Amount-of-substance concentration 0.0995 - 0.1005 mol/L
Measurement uncertainty ± 0.0003 mol/L
Traceability NIST SRM
TThe concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
Other Notes
Legal Information
signalword
Warning
hcodes
pcodes
Hazard Classifications
Met. Corr. 1
저장 등급
12 - Non Combustible Liquids
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
프로토콜
Method: Spectrophotometric Color Determination at 420 nm Zero adjustment For each measurement series, a zero adjustment is required. It is recommended to use the same cell for zero adjustment and for sample measurement. The zeroing procedure for the measurement series is automatically prompted by the instrument after entering the %RDS value.
APHA 10200-H는 추출용액의 측정에 대해 기술합니다. 위에서 명시한 시약을 이용하여 분석 방법을 영점 조정하면 분석용 정제수를 이용하여 분석 방법을 영점 조정했을 때와 비교 시 흡광도에 차이가 없었습니다. 그러므로 분석 방법을 영점 조정할 때 분석용 정제수 사용이 가능합니다.
문서
SmartChemicals enable wireless CoA data transfer, reducing human error in titration experiments.
관련 콘텐츠
칼 피셔 적정은 원료와 제품의 수분 함량을 측정하는 것으로, 널리 사용되는 분석 방법입니다.
Karl Fischer titration determines water content in raw materials and products, a widely used analytical method.
국제 무역 품목 번호
| SKU | GTIN |
|---|---|
| 1090601000 | 04022536110172 |
| 1090601003 | 04054839633300 |
| 1090604003 | 04054839633317 |
| 1090605003 | 04054839633324 |
| 1090604000 | 04027269029746 |
| 1090605000 | 04022536110196 |
| 1090609010 | 04022536110219 |
| 1090609013 | 04054839633331 |
| 1090609025 | 04022536110226 |