콘텐츠로 건너뛰기
Merck

C-153

Cannabinolic Acid (CBNA) solution

1.0 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
C22H26O4
CAS 번호:
Molecular Weight:
354.44
MDL number:
UNSPSC Code:
41116107
NACRES:
NA.24
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


grade

certified reference material

Quality Level

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

concentration

1.0 mg/mL in acetonitrile

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

application(s)

cannabis testing

format

single component solution

shipped in

dry ice

storage temp.

−70°C

SMILES string

O1C(c2c(cc(cc2)C)c3c1cc(c(c3O)C(=O)O)CCCCC)(C)C

InChI

1S/C22H26O4/c1-5-6-7-8-14-12-17-19(20(23)18(14)21(24)25)15-11-13(2)9-10-16(15)22(3,4)26-17/h9-12,23H,5-8H2,1-4H3,(H,24,25)

InChI key

KXKOBIRSQLNUPS-UHFFFAOYSA-N

General description

CThis Certified Spiking Solution® is suitable for cannabinolic acid testing methods by GC/MS, LC/MS or HPLC for applications in the testing of Cannabis potency or impurity profiling, pharmaceutical research, and forensic analysis. Cerilliant solution Certified Reference Materials (CRMs) of cannabinoids are supplied in a convenient, quantitative, US DEA-exempt solution format and with TK#s for Canadian customers.

Cannabinolic Acid is a non-psychoactive phytocannabinoid formed upon the oxidation of Δ9-THCA in Cannabis.

Application

The Certified Reference Material (CRM) in solution can also be used as follows:

  • Simultaneous determination of 16 phytocannabinoids in 27 samples of seized cannabis and 9 medicines based on cannabis by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
  • Quantitative analysis of 17 cannabinoids in cannabis and hemp samples by LC-MS/MS following their liquid-solid extraction following AOAC and ASTM guidelines for cannabis and hemp matrices
  • Liquid chromatographic (LC)-diode array detection (DAD) based separation and measurement of 20 cannabinoids from a variety of cannabis samples
  • Serum analysis to identify and quantify 18 phytocannabinoids by liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Features and Benefits

  • Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
  • Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
  • Rigorously tested through real-time stability studies to ensure accuracy and shelf life
  • Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
  • Flame sealed under argon into ampoules for long-term shelf life
  • Offered in a convenient, DEA-exempt format to improve laboratory efficiency

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Supply conditions do not apply to the regions and states of Brazil: North, Northeast, Mato Grosso do Sul, Mato Grosso, and Rio Grande do Sul.


pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

저장 등급

3 - Flammable liquids

wgk

WGK 2

flash_point_f

42.8 °F - closed cup

flash_point_c

6.0 °C - closed cup



시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문


프로토콜

HPLC separation of 17 important cannabinoids including CBD, delta 9 THC and THCA. Read the application note.

문서

ISO-certified cannabinoid CRMs, THC and THCA, available as single components or mixes, for accurate potency testing.

A complete workflow for the HPLC separation of 17 cannabinoids in different cannabis products using Ascentis® Express C18 Column in a shorter run time with retention time stability. Learn more here.

Overview of gradient HPLC-based cannabinoid analysis optimized for key method parameters.

모든 기사 보기

Awang Hazmi Awang-Junaidi et al.
Journal of animal science and biotechnology, 9, 8-8 (2018-01-27)
Gonocytes give rise to spermatogonial stem cells, and thereby play an essential role in establishing spermatogenesis. Optimized culture conditions for gonocytes provide an opportunity for their study and in vitro manipulation for potential application in reproductive technologies. Using six experiments
Tat-Chuan Cham et al.
Cells, 10(7) (2021-08-08)
The creation of a testis organoid (artificial testis tissue) with sufficient resemblance to the complex form and function of the innate testis remains challenging, especially using non-rodent donor cells. Here, we report the generation of an organoid culture system with



국제 무역 품목 번호

SKUGTIN
C-153-1ML04061838054722