material
polypropylene tube
Quality Level
제품 라인
Discovery®
구성
bed wt., 750 mg
포장
pk of 30
기술
solid phase extraction (SPE): suitable
표면적
480 m2/g
용적
6 mL
Matrix
silica gel (irregularly shaped, acid washed)
기질 활성군
benzenesulfonic acid bonding, Polymerically bonded, coated with silver ions
입자 크기
50 μm
공극 크기
0.9 mL/g pore volume
70 Å pore size
용량
less than or equal to 1 mg (total FAMEs)
응용 분야
food and beverages
분리 기술
normal phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Retention Mechanism: Normal phase (charge-transfer)
Sample Matrix Compatibility: Organic solvents, oils, and lipids
Sample Matrix Compatibility: Organic solvents, oils, and lipids
- Developed for the fractionation of FAMEs based on degree of unsaturation, and for the resolution of cis/trans isomers.
- Silver counter-ions are anchored onto an SCX support using a proprietary procedure to offer optimal resolution, performance, and capacity
- Each lot is tested and quality controlled for cis/trans FAME resolution
기타 정보
Keywords: silver ion, silver nitrate, AgNO3
법적 정보
Discovery is a registered trademark of Merck KGaA, Darmstadt, Germany
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1
Storage Class Code
13 - Non Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
Hirofumi Goto et al.
Journal of oleo science, 61(2), 49-56 (2012-01-27)
We developed a novel pre-separation method of trans fatty acids (TFAs) using a silver-ion cartridge column and GC. As a preliminary study, a mixture of fatty acid methyl esters consisting of saturated, cis-unsaturated, and trans-unsaturated fatty acids was dissolved in
Taeho Kim et al.
ACS applied materials & interfaces, 8(44), 30449-30457 (2016-10-19)
A theranostic nanoparticle with biochemically triggered antibacterial activity is demonstrated. Metallic silver is deposited onto porous silicon nanoparticles (pSiNPs) by galvanic displacement. When aqueous diaminesilver ([Ag(NH
Katsunori Anezaki et al.
Marine pollution bulletin, 113(1-2), 282-286 (2016-10-07)
We performed the first known study of polychlorinated biphenyls (PCBs) concentrations and patterns in the blubber and liver of a Hubbs' beaked whale. Samples were pretreated with Supelclean™ sulfoxide and Discovery® Ag-ION solid phase extraction cartridges to remove whale oil.
프로토콜
Fraction of cis/trans FAMEs Using Discovery® Ag-Ion SPE
Chromatograms
application for SPE, suitable for GC
suitable for GC, application for SPE
suitable for GC, application for SPE