콘텐츠로 건너뛰기
Merck

A1805

ACCUSPIN Tubes Sterile, 12 mL Capacity

radiation sterilized tube fitted with a high density polyethylene barrier

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

NACRES:
NA.75
UNSPSC Code:
12352207
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


Quality Level

sterility

sterile; irradiated

form

tubes

application(s)

hematology
histology

storage temp.

15-25°C

General description

ACCUSPIN™ Tubes are polypropylene radiation sterilized tube fitted with a high density polyethylene barrier. Each tube will accept 3mL of the density gradient.

Application

ACCUSPIN™ Tubes Sterile, 12 mL Capacity is intended for use with the density gradient separation medium Histopaque™ -1077:

  • in the isolation of lymphocytes and other mononuclear cells.
  • isolation of cord blood–derived endothelial progenitor cells.citation
  • isolate mononuclear cell layer from bone marrow samples.
  • suitable for the purification of human bone marrow aspirates for the investigation of the therapeutic value of BET inhibitors for acute myeloid leukemia.
  • isolation of cord blood-derived endothelial progenitor cells

Biochem/physiol Actions

Following the addition of Histopaque-1077 to the ACCUSPIN Tube, a brief centrifugation places the Histopaque-1077 below the frit. The blood sample can be added to the top chamber of the tube without the risk of mixing with the Histopaque-1077 in the lower chamber under the frit. On subsequent centrifugation the whole blood descends through the frit to contact with theHistopaque-1077. The elements of greater density displace a volume of Histopaque-1077 above the forgiving a clear separation of the blood components. The erythrocytes aggregate and the granulocytes become lightly hypertonic, increasing their sedimentation rate, resulting in pelleting at the bottom of the ACCUSPIN Tube. Lymphocytes and other mononuclear cells, e.g., monocytes, remain at the plasma/Histopaque-1077interface. This dense band of mononuclear cells maybe collected by pouring off the contents of the upper chamber or by means of a pipette. Erythrocyte contamination is avoided due to the barrier between the chambers.

Preparation Note

Package contains 20 tubes

Legal Information

Accuspin is a trademark of Sigma-Aldrich Co. LLC
Histopaque is a registered trademark of Merck KGaA, Darmstadt, Germany


pictograms

Health hazard

signalword

Danger

hcodes

Hazard Classifications

Resp. Sens. 1 - Skin Sens. 1

저장 등급

10 - Combustible liquids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable



가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문






국제 무역 품목 번호

SKUGTIN
A1805-20EA04061833343029