BCR048R

Benzo[k]fluoranthene

BCR®, certified reference material

로그인조직 및 계약 가격 보기

크기 선택


제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
C20H12
CAS 번호:
Molecular Weight:
252.31
Beilstein:
1873745
EC Number:
MDL number:
UNSPSC 코드:
41116107
PubChem Substance ID:
NACRES:
NA.24
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

Grade

certified reference material

Agency

BCR®

제조업체/상표

JRC

기술

HPLC: suitable
gas chromatography (GC): suitable

mp

215-217 °C (lit.)

solubility

95% ethanol: <1 mg/mL at 20 °C
DMSO: <1 mg/mL at 20 °C
H2O: <1 mg/mL at 20 °C
acetone: 1-10 mg/mL at 20 °C
methanol: <1 mg/mL at 20 °C
toluene: 5-10 mg/mL at 20 °C

형식

neat

저장 온도

2-8°C

SMILES string

c1ccc2cc-3c(cc2c1)-c4cccc5cccc-3c45

InChI

1S/C20H12/c1-2-6-15-12-19-17-10-4-8-13-7-3-9-16(20(13)17)18(19)11-14(15)5-1/h1-12H

InChI key

HAXBIWFMXWRORI-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

This compound is listed in the SVHC (Substances of very high concern) candidate list of ECHA (European Chemicals Agency)

분석 메모

For more information please see:
BCR048R

법적 정보

BCR is a registered trademark of European Commission

픽토그램

Health hazardEnvironment

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1B

Storage Class Code

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

개인 보호 장비

Eyeshields, Gloves, type P3 (EN 143) respirator cartridges


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

K L Willett et al.
Toxicology and applied pharmacology, 177(3), 264-271 (2001-12-26)
Certainpolynuclear aromatic hydrocarbons (PAHs) such as benzo[a]pyrene (BaP) induce CYP1A-dependent enzyme activities. Because PAHs are ubiquitous environmental contaminants, and some are aryl hydrocarbon agonists, CYP1A has been used as a biomarker for PAH exposure. However, PAHs exist in the environment
Hiroyuki Masaki et al.
The Analyst, 130(9), 1253-1257 (2005-08-13)
We developed a device and some systems for detecting benzo[a]pyrene (B[a]P) and benzo[k]fluoranthene (B[k]F). The device uses a UV light-emitting diode that emits light with a wavelength of 370 nm and a violet laser diode that emits light with a
Annekatrin Dreyer et al.
Environmental science & technology, 39(11), 3918-3924 (2005-06-30)
To date, studies about historic PAH (polycyclic aromatic hydrocarbons) deposition at a regional scale have rarely been published. To address this research gap, we sampled 17 ombrotrophic peatlands across eastern Canada. The peat cores from hollows were dated with 210Pb
Petra Booij et al.
Environmental toxicology and chemistry, 30(4), 898-904 (2010-12-31)
In bioassays, exposure concentrations of test compounds are usually expressed as nominal concentrations. As a result of various processes, such as adsorption, degradation, or uptake, the actual freely dissolved concentration of the test compound may differ from the nominal concentration.
Shan Chen et al.
Environmental science & technology, 42(24), 9431-9436 (2009-01-30)
Japanese medakas (Oryzias latipes) and triolein-embedded cellulose acetate membranes (TECAMs) were exposed simultaneously to benzo[k]fluoranthene (BkF) in the static exposure system containing different concentrations of humic acid (HA). The concentration-response relationships of induced hepatic 7-ethoxysorufin-o-deethylase (EROD) activity were established in