1.03725
Acetonitrile
≥99.9% (GC), suitable for UHPLC, LiChrosolv®
Synonym(s):
ACN, Cyanomethane, Ethyl nitrile, Methyl cyanide
Select a Size
About This Item
LC/MS: suitable
UHPLC: suitable
97 hPa ( 20 °C)
Product Name
Acetonitrile, for UHPLC-MS LiChrosolv®
Agency
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 8327
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
Quality Level
reg. compliance
suitable for FDA C-010.02
vapor density
1.41 (vs air)
vapor pressure
72.8 mmHg ( 20 °C)
97 hPa ( 20 °C)
product line
LiChrosolv®
Assay
≥99.9% (GC)
form
liquid
autoignition temp.
524 °C
973 °F
expl. lim.
16 %
technique(s)
HPLC: suitable
LC/MS: suitable
UHPLC: suitable
refractive index
n20/D 1.344 (lit.)
bp
81-82 °C (lit.)
mp
−45 °C (lit.)
transition temp
flash point 2 °C
density
0.786 g/mL at 25 °C (lit.)
SMILES string
CC#N
application(s)
PFAS testing
format
neat
storage temp.
2-30°C
InChI
1S/C2H3N/c1-2-3/h1H3
InChI key
WEVYAHXRMPXWCK-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
General description
Acetonitrile is a polar aprotic solvent, which is used as an intermediate in organic synthesis. It has a low viscosity, high elution strength and miscibility in water that make it viable in many chromatography systems. It can also be utilized in spectrophotometric and fluorimetric technques.
Application
Featured as a solvent in screening of benzofurans and ethylphenidate psychostimulants in serum, urine, and hair samples by UHPLC-MS/MS.
The product is an organic solvent, used as a mobile phase/extraction solvent in the ultra-high performance liquid chromatorgraphy - tandem mass spectrometry (UHPLC-MS/MS) analysis of pesticides in tobacco samples.
Other Notes
Legal Information
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point(F)
35.6 °F - closed cup
Flash Point(C)
2.0 °C - closed cup
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Compare columns in resolving medium-sized antibody fragments after digestion with DTT or IdeS using Reversed-Phase Chromatography for analysis.
We present a fast and robust HPLC-MS/MS method that can be used for Remdesivir and three structural antiviral analogues
Polar graphitic carbon enables UHPLC separation of highly polar pesticides, herbicides, and Vitamin D metabolites, advancing liquid chromatography capabilities.
Learn how filter selection and sample and mobile phase filtration impact HPLC back pressure and column lifetime.
Protocols
A complete workflow for the intact and middle-up mass analysis of reduced and non-reduced monoclonal antibodies based on SEC-MS with sample preparation by protein-A affinity clean-up.
SEC-MS protocol for rapid glycoprofiling of monoclonal antibodies with antibody purification and mass spectrometer calibration.
Related Content
전체 솔루션을 알아보세요. 신뢰할 수 있는 제품과 정밀한 툴로 물, 폐수, 흙, 식품, 혈액 등이 포함된 다양한 샘플에서 PFAS 화합물의 양을 더욱 정확하게 측정할 수 있습니다.
저분자는 일반적으로 분자량이 900달톤 미만인 이온 및 화합물입니다. 이러한 화합물은 주로 실리카 입자 또는 다양한 컬럼 화학(변형)을 가진 모놀리식 고정상을 사용하여 HPLC, UHPLC 및 LC-MS로 효과적으로 분리 및 분석할 수 있습니다.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service