03-0186-00
SMC® Human IFN-α2 High Sensitivity Immunoassay Kit
Synonym(s):
IFN-alpha-2 Single Molecule Counting Kit, IFN-alpha-2 immunoassay kit, IFN-alpha-2 ultra-sensitive immunoassay, Interferon alpha-A immunoassay kit
Select a Size
About This Item
description
LLOQ range: 0.015-0.123 pg/mL, refer to CoA for lot-specific LLOQ
species reactivity
canine, feline, porcine, rat, nonhuman primates
manufacturer/tradename
SMC®
assay range
sensitivity: 0.062 pg/mL
(lower limit of quantification)
inter-assay cv: <13%
intra-assay cv: <9%
technique(s)
ELISA: suitable
single molecule counting: suitable
relevant disease(s)
autoimmune diseases
storage temp.
2-8°C
General description
The SMC® Human IFN-α2 High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format.
Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and SMCxPRO® immunoassay systems detect analytes using Single Molecule Counting (SMC®) technology.
Application
- Inflammation & Immunology
Research Sub-Category:
- Inflammatory Disease
- Immune Response
- Autoimmune disease
The sensitivity of the Single Molecule Counting (SMC®) technology gives the SMC® Human IFN-a2 High Sensitivity Immunoassay Kit unparalleled performance in the quantification of IFN-a2 in human serum and plasma.
Biochem/physiol Actions
This assay was tested for cross reactivity with rhIFN-β, rhIFN-γ, rhIFN-λ1 (IL-29), rhIFN-λ2 (IL28A), rhIFN-λ3 (IL-28B), rhIFN-ω, IFN-α2a, IFN-α2b and IFN-α.
- There is no cross-reactivity detected with rhIFN-ß, rhIFN-γ, rhIFN-λ1 (IL-29), rhIFN-λ2 (IL-28A),rhIFN-λ3 (IL-28B), and rhIFN-ω.
- There is 100% cross-reactivity with IFN-α2a.
- There is 49% cross-reactivity with IFN-α2b.
- There is 3% cross-reactivity with IFN-α.
Accuracy:
- Minimum of 5 serum samples spiked with average recovery of 102% with a range of 92-111%
- Minimum of 5 plasma samples spiked with average recovery of 96% with a range of 89-107%
Features and Benefits
- Improved options for sample prep and incubation
- Lyophilization of the standard provides the kit at one storage condition
- Removal of a plate transfer step
- Increased reagent volumes to accommodate automation
- Validated to run on both SMCxPRO® and Erenna
Analysis Note
Other Notes
- Assay Buffer
- IFN-a2 Coated Beads
- Standard Diluent
- IFN-a2 Detection Antibody
- IFN-a2 Standard
- 10X Wash Buffer
- Buffer D
- Elution Buffer B
Legal Information
Disclaimer
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
Use the power of high sensitivity immunology assays with SMC® technology to precisely characterize low-abundant cytokines like those from Th1/Th2 and Th17 cells.
Explore ultrasensitive immunoassay technology with SMC® technology, including its biomarker detection platform, advantages of high sensitivity assays, and more.
SMC® 기술을 활용하여 Th1/Th2 및 Th17 세포와 같이 낮은 수준의 사이토카인을 정확하게 특성화함으로써 고감도 면역학 분석의 힘을 통해 면역학 연구를 향상시키는 방법을 알아보세요.
단일분자계수 (Single Molecule Counting, SMC®) 기술을 사용한 초고감도 분석 기술 개요를 살펴보십시오. 이에는 해당 기술의 워크플로, 바이오마커 감지 플랫폼, 연구 영역, 고감도 SMC 검사의 장점 등이 포함되어 있습니다.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service