53572-U

Ascentis® Express 160 Å PFAS (2.7 μm) Delay HPLC Columns

L × I.D. 5 cm × 3.0 mm, HPLC Delay Column; suitable for PFAS testing

Synonym(s):

Ascentis® Express 160 Å PFAS Delay, 2.7 μm HPLC Column

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View

About This Item

UNSPSC Code:
41115709
NACRES:
SB.52
Particle size:
2.7 μm
Matrix active group:
highly retentive endcapped silane bonding phase
Pore size:
160 Å pore size
Matrix:
Fused-Core® silica particle platform particle platform, superficially porous particle
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Ascentis® Express 160 Å PFAS (2.7 μm) Delay HPLC Columns, column L × I.D. 5 cm × 3.0 mm, suitable for PFAS testing

material

stainless steel column

Quality Level

agency

suitable for ASTM® 7968, suitable for ASTM® 7979, suitable for DIN 38407-42, suitable for EPA 533, suitable for EPA 537.1, suitable for EPA 8327, suitable for EPA ACB B21-02, suitable for EPA ACB B23-05b, suitable for EPA OTM-45, suitable for GB 31604.35-2016, suitable for GB 5009.253-2016, suitable for ISO 21675 2019, suitable for ISO 25101, suitable for ISO/CEN 15968-2010, suitable for USP L62

reg. compliance

suitable for FDA C-010.02

product line

Ascentis®

feature

endcapped

packaging

1 ea of

parameter

≤60 °C temp. limit, ≤9000 psi max. pressure (600 bar)

technique(s)

HPLC: suitable, LC/MS: suitable

column L × I.D.

5 cm × 3.0 mm

surface area

90 m2/g

matrix

Fused-Core® silica particle platform particle platform, superficially porous particle

matrix active group

highly retentive endcapped silane bonding phase

particle size

2.7 μm

pore size

160 Å pore size

operating pH range

2-9

application(s)

PFAS testing

separation technique

reversed phase

General description

Ascentis® Express PFAS Delay is a high-performance liquid chromatography column based on Fused-Core® particle design. The highly retentive endcapped silane of the Ascentis® Express PFAS Delay column provides high retention of PFAS compounds across various mobile phase conditions and is used to delay background instrument PFAS contamination from interference with analyzed samples. For this reason, the Ascentis® Express PFAS Delay column is placed upstream of the sample injector.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.


Still not finding the right product?




Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

Sensitive PFAS testing can be performed with ultrapure water from a Milli-Q® IQ 7 system, which eliminates detectable PFAS for reliable LC-MS/MS results. See the science, see the proof.

Learn how method EPA 533 is used for sample collection and preparation, featuring Supelclean™ ENVI-WAX™ SPE cartridges for LC-MS analysis on an Ascentis® Express PFAS HPLC Column.

Simultaneous determination of 27 PFAS chemical compounds after enriching the water samples with SPE using a Supelclean® ENVI-WAX weak anion exchange tube.

View All Articles

Related Content

Las PFAS o «productos químicos eternos», persisten en el medio ambiente y pueden suponer un riesgo para la salud humana. Descubra nuestras herramientas de control medioambiental para cuantificación de las PFAS, para apoyar a los investigadores, reguladores y laboratorios en sus análisis de las PFAS.





Global Trade Item Number

SKUGTIN
53572-U04065266561456